    Penetrometers

    SETUP -> Penetrometers or QUALITY -> Maturity samples -> Setup menu -> Penetrometers

    To integrate penetrometers with snapPacking's maturity samples, you require a special program to be installed on your computer. Penetrometer details will automatically be set at the recommended defaults but can be maintained here.

    • Description - name.
    • Type - type/version of penetrometer.
    • Com. port - computer comm port the scanner is plugged into.
    • Notes
    • Sample depth - this is the depth the penetrometer goes into the apple in tenth of millimetre. Minimum value is 10 (1.0mm) and maximum is 250 (25.0mm).
    • Sample speed - speed of the penetrometer in mm/sec. Minimum value is 8mm/sec and maximum is 25mm/sec.
    • Sample trigger grams - trigger threshold in grams. Minimum is 30g and maximum is 250g.
    • Sample yield drop KG
    • Sample min. Kgs

    The information on the right hand side of the screen will help identify any issues, ie if the service is not running and/or penetrometer isn't communicating with the computer.